Industrial control advisorySeverity 4.4 medium
Hitachi Energy PCM600 (Update A)
ICSA-26-125-01 · CISA · April 28, 2026
Summary
Hitachi Energy is aware of a vulnerability that affects the Hitachi Energy PCM600 product versions listed in this document. An attacker successfully exploiting this vulnerability can impact integrity of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.
From CISA, quoted as published. Check the source before acting.
What to do
Please see the PCM600 Legacy Versions section below
Ensure that Chapter 4 of Cyber Security Deployment Guideline - 1MRK505410 has been followed during the deployment. Ensure that no default credentials are in use. In case of exceptions, please ensure they have been mitigated with adequate countermeasures.
Update to PCM600 3.1 SP4
Vendor fix or mitigation, quoted from the advisory.
Each CVE in this advisory
| CVE | Severity | Known exploited | Exploit likelihood |
|---|---|---|---|
| CVE-2018-1002208 | 4.4 medium | No | 9.9% |
Severity from the advisory (CVSS), known exploitation from CISA's catalog, exploit likelihood from EPSS (next 30 days).
Affected products
| Vendor | Product |
|---|---|
| Hitachi Energy | PCM600 Legacy |
| Hitachi Energy | PCM600 |
Why it's on these mode pages
- Maritime: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
- Pipeline: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
- Freight rail: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
- Passenger rail and transit: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
- Highway and motor carrier: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
- Postal and parcel: Vendor table: Hitachi Energy (industrial control makers used in every mode, all modes) (matched by rule)
Change history
- April 28, 2026: Initial public release
- May 5, 2026: CISA Republication - Initial CISA Republication of Hitachi Energy 8DBD000239 advisory
- October 27, 2026: Remediation released in PCM600 v3.1 SP4 on 16-09-2026