Public preview. Built from real public data on November 9, 2026, 5:41 AM UTC.
Securidigm Watch Transportation cyber intel
Home / Items
Industrial control advisorySeverity 7.7 high

Siemens SIMATIC IPCs

ICSA-26-295-07 · CISA · October 13, 2026

Summary

The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions.

From CISA, quoted as published. Check the source before acting.

What to do

<br/>Note: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. <br/>Note: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards. As a temporary mitigation, users can manually remove the test key from the database (e.g., "DO NOT TRUST - AMI Test PK" for RW-543A or "insyde-ElkhartLake" for IPC227G/277G/327G/377G and BX-21A). Note: Loading default settings will restore the test key, so upgrading remains recommended. Update to V1.1.4 or later version Update to V28.01.15 or later version Update to V31.01.13 or later version

Vendor fix or mitigation, quoted from the advisory.

Each CVE in this advisory

CVESeverityKnown exploitedExploit likelihoodWeakness
CVE-2026-728957.7 highNo0.1%Use of Default Cryptographic Key (CWE-1394)

Severity from the advisory (CVSS), known exploitation from CISA's catalog, exploit likelihood from EPSS (next 30 days).

Affected products

VendorProductAffected versionsFixed
SiemensSIMATIC IPC BX-21Avers:intdot/<31.01.13—
SiemensSIMATIC IPC RW-543Avers:intdot/<1.1.4—
SiemensSIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377Gvers:intdot/<28.01.15—

Why it's on these mode pages

  • Maritime: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
  • Pipeline: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
  • Freight rail: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
  • Passenger rail and transit: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
  • Highway and motor carrier: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
  • Postal and parcel: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)

Change history

  1. October 13, 2026: Publication Date
  2. October 22, 2026: Initial CISA Republication of Siemens ProductCERT SSA-159454 advisory
  3. November 9, 2026: First collected by Watch

Securidigm Scout can match advisories like this one to the equipment on your own network, offline. securidigm.com