Home / Items
Vendor advisorySeverity 7.3 high
SSA-392859: Local Arbitrary Code Execution Vulnerability in Siemens Engineering Platforms before V20
SSA-392859 · Siemens · December 10, 2024
Summary
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
Siemens has released products based on the Totally Integrated Automation Portal (TIA Portal) V20 which are not affected by CVE-2024-52051. See the chapter "Additional Information" below for more details.
From Siemens (vendor's own words, quoted), quoted as published. Check the source before acting.
What to do
Currently no fix is planned
Currently no fix is available
Update to V17 Update 9 or later version
Update to V18 Update 6 or later version
Vendor fix or mitigation, quoted from the advisory.
Each CVE in this advisory
| CVE | Severity | Known exploited | Exploit likelihood |
|---|---|---|---|
| CVE-2024-52051 | 7.3 high | No | 0.2% |
Severity from the advisory (CVSS), known exploitation from CISA's catalog, exploit likelihood from EPSS (next 30 days).
Affected products
| Vendor | Product |
|---|---|
| Siemens | SIMATIC S7-PLCSIM V17 |
| Siemens | SIMATIC S7-PLCSIM V18 |
| Siemens | SIMATIC STEP 7 Safety V17 |
| Siemens | SIMATIC STEP 7 Safety V18 |
| Siemens | SIMATIC STEP 7 Safety V19 |
| Siemens | SIMATIC STEP 7 V17 |
| Siemens | SIMATIC STEP 7 V18 |
| Siemens | SIMATIC STEP 7 V19 |
| Siemens | SIMATIC WinCC Unified PC Runtime V18 |
| Siemens | SIMATIC WinCC Unified PC Runtime V19 |
| Siemens | SIMATIC WinCC Unified V17 |
| Siemens | SIMATIC WinCC Unified V18 |
| Siemens | SIMATIC WinCC Unified V19 |
| Siemens | SIMATIC WinCC V17 |
| Siemens | SIMATIC WinCC V18 |
| Siemens | SIMATIC WinCC V19 |
| Siemens | SIMOCODE ES V17 |
| Siemens | SIMOCODE ES V18 |
| Siemens | SIMOCODE ES V19 |
| Siemens | SIMOTION SCOUT TIA V5.4 |
| Siemens | SIMOTION SCOUT TIA V5.5 |
| Siemens | SIMOTION SCOUT TIA V5.6 |
| Siemens | SINAMICS Startdrive V17 |
| Siemens | SINAMICS Startdrive V18 |
| Siemens | SINAMICS Startdrive V19 |
| Siemens | SIRIUS Safety ES V17 (TIA Portal) |
| Siemens | SIRIUS Safety ES V18 (TIA Portal) |
| Siemens | SIRIUS Safety ES V19 (TIA Portal) |
| Siemens | SIRIUS Soft Starter ES V17 (TIA Portal) |
| Siemens | SIRIUS Soft Starter ES V18 (TIA Portal) |
| Siemens | SIRIUS Soft Starter ES V19 (TIA Portal) |
| Siemens | TIA Portal Cloud V17 |
| Siemens | TIA Portal Cloud V18 |
| Siemens | TIA Portal Cloud V19 |
Why it's on these mode pages
- Maritime: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
- Pipeline: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
- Freight rail: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
- Passenger rail and transit: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
- Highway and motor carrier: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
- Postal and parcel: Vendor table: Siemens (industrial control makers used in every mode, all modes) (matched by rule)
Change history
- December 10, 2024: Publication Date
- August 12, 2025: Added fix for Totally Integrated Automation Portal (TIA Portal) V19; Name of SIMOTION SCOUT TIA V5.6 SP1 was updated to SIMOTION SCOUT TIA V5.6 and Name of SIMOTION SCOUT TIA V5.5 SP1 was updated to SIMOTION SCOUT TIA V5.5 and Name of SIMOTION SCOUT TIA V5.4 SP3 was updated to SIMOTION SCOUT TIA V5.4
- December 9, 2025: Added fix for Totally Integrated Automation Portal (TIA Portal) V17
- October 13, 2026: Added no fix expected for PLCSIM, SIMATIC STEP 7 Safety V18, SIMATIC STEP 7 V18, SIMATIC WinCC Unified V18, SIMATIC WinCC V18
- November 9, 2026: First collected by Watch
Securidigm Scout can match advisories like this one to the equipment on your own network, offline. securidigm.com